Sign In | Join Free | My ecer.co.uk
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > ECG Machine Parts >

EDAN ECG Cable 5 Lead 6 Pin Defib Snap AHA Reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

EDAN ECG Cable 5 Lead 6 Pin Defib Snap AHA Reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016

Brand Name : Edan ECG Cable

Model Number : 01.57.471472016

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : Edan ECG Cable

Type : 01.57.471472016

Application : ECG medical equipment,ICU,hospital device

Warranty : 90days

Features : Professional, reliable,Economic

Stock Status : Sufficient inventory

Power supply source : Electric

Mode of transport : Express delivery

AC Input Voltage Rate : 110V— 240v

Minimum purchase contract : 1 pcs

Languages : Multi-lingual Support

Services : Online technical support

Contact Now

EDAN ECG cable 5-lead,6pin,defib, snap,AHA, reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016

►Brief Introduction

Monitoring the ECG produces a continuous waveform of a patient's heart's electrical activity, enabling an accurate assessment of their current physiological state. Only the correct connection of the ECG cable can ensure a satisfactory measurement.

This ECG Cable compatible with EDAN Vital Sign Monitors M3, M3A, iM3, iM50, iM60, iM60, iM70, iM80 Patient monitor.


► Electrode placement for the 5-lead set

Take the American standard for example, see the following figure:

  • RA placement: directly below the clavicle and near the right shoulder.
  • LA placement: directly below the clavicle and near the left shoulder.
  • RL placement: on the right hypogastrium.
  • LL placement: on the left hypogastrium.
  • V placement: on the chest, the position depends on your required lead selection.

EDAN ECG Cable 5 Lead 6 Pin Defib Snap AHA Reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016

Using 5-lead ECG Set

You can set the leads on ECG CH1 and ECG CH2 according to your needs. The lead label is displayed on the upper left part of the waveform. You can set them corresponding to any two from I, II, III, AVR, AVL, AVF and V1~V6. If you set both to the same value, one of them will be adjusted to another option automatically.

Notice:

1 If the ECG waveform is inaccurate and the electrodes are tightly connected, try changing the lead.

2 Interference from non-grounded instruments near the patient and ESU interference can cause inaccurate waveforms.

► Range of Sinus and SV Rhythm

Tachy ADU: 120 bpm ~ 300 bpm
PED/NEO: 160 bpm ~ 350 bpm
Normal ADU: 41 bpm ~ 119 bpm
PED/NEO: 61 bpm ~159 bpm
Brady ADU: 15 bpm ~ 40 bpm
PED/NEO: 15 bpm ~ 60 bpm

► Preparing the Skin

Thorough skin preparation is very important. The skin is a poor conductor of electricity and frequently creates artifacts that distort the ECG signals. By performing methodical skin preparation, you can greatly reduce the possibility of noise caused by muscle tremor and baseline drift, ensuring high-quality ECG waves. There is natural resistance on the skin surface due to dry, dead epidermal cells, oils and dirt.

To Prepare the Skin

  1. Shave hair from electrode sites, if necessary. Excessive hair prevents a good connection.
  2. Wash the area thoroughly with soap and water.
  3. Dry the skin with a gauze pad to increase capillary blood flow to the tissues and to remove the dead, dry skin cells and oils.

NOTE: If you don’t have enough time for the steps above, you can use pledget to scrub the electrode sites to remove the dead, dry skin cells and oils and increase capillary blood flow to the tissues.

If you want to explore more details about EDAN ECG cable 5-lead,6pin,defib, snap,AHA, reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016 , please let us know. Looking forward to receiving your early inquiry.


Product Tags:

6 Pin ECG Cable

      

3.4M ECG Cable

      

EC05DAS061 ECG Cable

      
Quality EDAN ECG Cable 5 Lead 6 Pin Defib Snap AHA Reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016 for sale

EDAN ECG Cable 5 Lead 6 Pin Defib Snap AHA Reusable 3.4M REF EC05DAS061 IPN 01.57.471472 MPN 01.57.471472016 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)